Exponential trends in flowback chemistry from a hydraulically stimulated deep geothermal borehole in granite; Pohang, South Korea

Urheber*innen

Banks,  David
External Organizations;

Burnside,  Neil
External Organizations;

Westaway,  Rob
External Organizations;

/persons/resource/zimm

Zimmermann,  G.
4.8 Geoenergy, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum;

/persons/resource/hannes

Hofmann,  Hannes
4.8 Geoenergy, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (frei zugänglich)

4539902.pdf
(Verlagsversion), 633KB

Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Banks, D., Burnside, N., Westaway, R., Zimmermann, G., Hofmann, H. (2019): Exponential trends in flowback chemistry from a hydraulically stimulated deep geothermal borehole in granite; Pohang, South Korea. - E3S Web of Conferences, 98, 08001.
https://doi.org/10.1051/e3sconf/20199808001


Zitierlink: https://gfzpublic.gfz-potsdam.de/pubman/item/item_4539902
Zusammenfassung
Samples of flowback water from a 4.3 km deep geothermal borehole in granite (Pohang, South Korea) were collected following a period of hydraulic stimulation by injection of surface water. Electrical conductivity, temperature and water chemistry of the flowback water were measured. To a first approximation, the data conform closely to a simple ‘mixing tank’ model, with an exponential trend between two end members: an initial injected surface water to a more brackish ‘resident groundwater’ composition. Significant deviation from the ‘mixing tank’ trend would be an indication of significant recent water-rock interaction or other anomalous factors. Such a deviation can tentatively be seen in Na+/Cl- data, especially between 88 and 200 m3 flowback (2.8 to 8.8 hr).