Deutsch
 
Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Improving data quality in long-term Canadian ozone sounding records

Tarasick, D., Stauffer, R. M., Smit, H. G. J., Thompson, A. M., Davies, J., Van Malderen, R., Johnson, B., Vömel, H. (2023): Improving data quality in long-term Canadian ozone sounding records, XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG) (Berlin 2023).
https://doi.org/10.57757/IUGG23-4503

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Tarasick, David1, Autor
Stauffer, Ryan M.1, Autor
Smit, Herman G. J.1, Autor
Thompson, Anne M.1, Autor
Davies, Jonathan1, Autor
Van Malderen, Roeland1, Autor
Johnson, Bryan1, Autor
Vömel, Holger1, Autor
Affiliations:
1IUGG 2023, General Assemblies, 1 General, International Union of Geodesy and Geophysics (IUGG), External Organizations, ou_5011304              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The importance of long-term ozonesonde records as a stable reference has led to increased attention to quantifying uncertainties and changes in ozonesonde data. The recent Assessment of Standard Operating Procedures for Ozone Sondes (ASOPOS 2.0; WMO/GAW Report #268) recommended that homogeneity and long-term stability in ozone sounding network time series be evaluated regularly by comparison with satellite sensors, as well as ground-based photometers.An abrupt change in ozone bias relative to several satellite sensors – a total column ozone (TCO) “dropoff” of about 2-3% – has been reported at number of ozonesonde stations (Stauffer et al., 2020), including Canadian stations. The dropoff affects stratospheric measurements from the EnSci ozonesonde, after 2013 (approximately serial number 26000). The Canadian network recently switched to Science Pump sondes (after serial number 32000), and this has reversed the dropoff, and approximately restored agreement with satellite sensors.It is not standard practice to calibrate individual ozonesonde pumps before launch, as this is difficult and labour-intensive; rather an average pump calibration is used in data processing. Recently, an analysis of an extensive record of individual EnSci pump calibrations made since 2009 (Nakano and Morofuji, 2022) has shown a small negative shift in the low-pressure pump correction, equal to 2% at 20 hPa and 4% at 10 hPa. This agrees very well with the average differences found with MLS at 31 hPa and 10 hPa, for Canadian data. The use of these new pump corrections with Canadian data is explored, and results are compared to MLS, and other satellite sensors.

Details

einblenden:
ausblenden:
Sprache(n): eng - Englisch
 Datum: 2023-07-112023-07-11
 Publikationsstatus: Final veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.57757/IUGG23-4503
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG)
Veranstaltungsort: Berlin
Start-/Enddatum: 2023-07-11 - 2023-07-20

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Potsdam : GFZ German Research Centre for Geosciences
Seiten: - Band / Heft: - Artikelnummer: - Start- / Endseite: - Identifikator: -