English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  CO2 emission assessment of the geothermal power station Los Humeros, Mexico

Gonzalez Garcia, H., Francke, H., Göllner-Völker, L., Welsch, B., Kranz, S., Huenges, E., Schebeck, L., Sass, I. (2022): CO2 emission assessment of the geothermal power station Los Humeros, Mexico. - Geothermics, 104, 102471.
https://doi.org/10.1016/j.geothermics.2022.102471

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Gonzalez Garcia, H1, Author              
Francke, H.1, Author              
Göllner-Völker, L.2, Author
Welsch, B.2, Author
Kranz, S.1, Author              
Huenges, Ernst1, Author              
Schebeck, L.2, Author
Sass, Ingo1, Author              
Affiliations:
14.8 Geoenergy, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146039              
2External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: This work presents the estimation of the CO2eq emissions of the geothermal power station in Los Humeros, Mexico. The calculation takes the emissions of the CO2 contained on the extracted geothermal brine plus the CO2 footprint by the power station construction. The carbon footprint estimation is based on technical reports generated by the owner company. It considers all the commissioning activities and also the operational phase of the power plant, which is assumed to span a lifetime of 30 years. The results indicate a total emission from 442 to 568 . Of these emissions 9 to 12% are contributed indirectly by the power station construction whereas 88 to 91% are released directly during operations due to the natural content of CO2 in the steam. When comparing the results with the natural discharge of CO2 in the production area, the emissions of CO2eq is 10 times faster. Solutions are proposed to reduce the footprint of CO2eq per kWhel. In the short term the use of all the installed capacity in the field reduces the footprint by 25%. Another option is to use closed cycle technology with a binary power station instead of the single-flash power plants. This showed 82% reduction of CO2eq emissions; accompanied by a reduction of electricity production by 16% due to the lower conversion efficiency.

Details

show
hide
Language(s):
 Dates: 20222022
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.geothermics.2022.102471
GFZPOF: p4 T8 Georesources
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Geothermics
Source Genre: Journal, SCI, Scopus
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 104 Sequence Number: 102471 Start / End Page: - Identifier: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/journals188
Publisher: Elsevier