English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  New thermocronological data of the Cretaceous-Cenozoic clastic sequences from the VINCHINA basin: Linkage between burial, exhumation and thermal flow variations

Wunderlin, C., Collo, G., Parra, M., Ezpeleta, M., Sánchez Nassif, F., Flores, M., Sobel, E. R., Glodny, J. (2021): New thermocronological data of the Cretaceous-Cenozoic clastic sequences from the VINCHINA basin: Linkage between burial, exhumation and thermal flow variations. - Journal of South American Earth Sciences, 105, 102964.
https://doi.org/10.1016/j.jsames.2020.102964

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Wunderlin, Cecilia1, Author
Collo, Gilda1, Author
Parra, Mauricio1, Author
Ezpeleta, Miguel1, Author
Sánchez Nassif, Francisco1, Author
Flores, Marlene1, Author
Sobel, Edward R.1, Author
Glodny, J.2, Author              
Affiliations:
1External Organizations, ou_persistent22              
23.1 Inorganic and Isotope Geochemistry, 3.0 Geochemistry, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146040              

Content

show
hide
Free keywords: AFT,(U–Th)/He, Inverse thermal modeling, Thermal regime, Vinchina basin, Cretaceous-Cenozoic sedimentary basin
 Abstract: New apatite fission track (AFT) and (U–Th)/He (AHe) data from two sections recording Cretaceous-Cenozoic clastic successions (La Flecha - La Troya Sur creeks) in the northern sector of the Central Precordillera of Argentina are presented. The results show that the Ciénaga del Río Huaco, Puesto la Flecha and Vallecito Fms. would have crossed the 60 °C isotherm during burial, while the middle sector of the Vinchina Fm. would not have reached temperatures higher than 55 °C. Multimethod inverse thermal modeling suggests that the AFT ages of all the studied levels would not have been completely reset and allow inferring that the partial retention zone for the AHe system (AHe-PRZ) would have been reached during the Miocene in levels between the Vallecito and Vinchina Fms. Our 1D-modeling results for the Ciénaga del Río Huaco, Puesto la Flecha and Vallecito Fms. show that the maximum temperature would have been reached at ~15 Ma, with a sedimentary thickness of ~2750 m and a heat flow of 65 mW/m2. From these data, a geothermal gradient of ~27 °C/km at this time could be inferred. In turn, the Vinchina and Zapallar Fms. would have reached their maximum temperature at ~2 Ma, under a cooler thermal regime (20 mW/m2) and with an estimated geothermal gradient of <15 °C/km. Thus, a complex time-temperature trajectory is proposed. Maximum and cooling temperatures reached by each unit do not correspond in all cases to the maximum burial and exhumation times. Comparison of the thermal modelling from this work with those carried out by other authors for sections immediately to the north allows us to infer that the thermal regime within the Vinchina basin has important lateral variations. Finally, AFT and AHe analyzes carried out in this work constitute a baseline database of the thermal regime, which is necessary for future multiproxies studies that are being done to evaluate the preservation of primary thermal signals, and thus check their reliability for pealeoclimatic and paleoenvironmental interpretations.

Details

show
hide
Language(s): eng - English
 Dates: 2020-10-142020-11-052021
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.jsames.2020.102964
GFZPOF: p3 PT2 Plate Boundary Systems
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of South American Earth Sciences
Source Genre: Journal, SCI, Scopus
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 105 Sequence Number: 102964 Start / End Page: - Identifier: ISSN: 0895-9811
Other: Elsevier
CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/journals305
Publisher: Elsevier