English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Energy balance of the carbon dioxide injection facility in Ketzin, Germany

Wiese, B., Nimtz, M. (2019): Energy balance of the carbon dioxide injection facility in Ketzin, Germany. - Applied Energy, 239, 626-634.
https://doi.org/10.1016/j.apenergy.2019.01.223

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Wiese, B.1, Author              
Nimtz, Michael2, Author
Affiliations:
14.8 Geoenergy, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146039              
2External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Injection of 67 kt carbon dioxide was carried out between 2008 and 2013 at the test site for geological storage in Ketzin, Germany. The source carbon dioxide was delivered in liquid phase. The injection facility has had a three step process chain: (i) pressure increase by a liquid pump, (ii) temperature increase by ambient air vaporizers and (iii) temperature increase by an electrical vaporizer including phase change to gaseous conditions. The ambient vaporizers reduced electrical power demand but the weather dependence induced some kind of uncertainty, further their power could not be measured. In the cases when the carbon dioxide was evaporated within the ambient vaporizers, the heat demand increased such that the driving temperature was not enough for full vaporization. However, the gas to liquid ratio is unknown wherefore the heating power can not be calculated over the ambient vaporizer. This is addressed, as the electric energy consumption was most reduced during the two phase operation. For these intervals, two phase gas–liquid conditions prevailed in the pipeline. Unlike conjectured, flow conditions remained stable and did not vary significantly from single phase behavior. The current work – for the first time – presents a detailed analysis of energy input and losses of the carbon dioxide injection process based on field data and simulations. A modified process chain is proposed to switch the electric energy demand to an ambient heat source, reducing the electrical energy use per ton carbon dioxide by up to 90 %. The work provides insight for planning future injection devices that involve liquid carbon dioxide in the process chain.

Details

show
hide
Language(s): eng - English
 Dates: 2019
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: GFZPOF: p3 PT5 Georesources
DOI: 10.1016/j.apenergy.2019.01.223
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Applied Energy
Source Genre: Journal, SCI, Scopus
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 239 Sequence Number: - Start / End Page: 626 - 634 Identifier: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/0910