English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Mechanical and optical tests of Zeiss THEO 010 and 020 nonmagnetic theodolites during the IAGA workshop 2018 at Conrad Observatory

Matzka, J., Wenger, T., Krüger, J., Morschhauser, A. (2019): Mechanical and optical tests of Zeiss THEO 010 and 020 nonmagnetic theodolites during the IAGA workshop 2018 at Conrad Observatory. - In: Leonhardt, R., Leichter, B. (Eds.), 18th Workshop an Geomagnetic Observatory Instruments, Data Acquisition and Processing of the International Association of Geomagnetism and Aeronomy (IAGA), Conrad Observatory Journal - COBS Journal: Special issue; 5, 2018, Wien : Zentralanstalt für Meteorologie und Geodynamik, 19.

Item is

Files

show Files
hide Files
:
COBSJournal-template_Matzka_et_al_theodolite_test_workshop.pdf (Publisher version), 263KB
Name:
COBSJournal-template_Matzka_et_al_theodolite_test_workshop.pdf
Description:
-
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
Conrad Observatory Journal No. 5

Creators

show
hide
 Creators:
Matzka, J.1, Author              
Wenger, T.2, Author
Krüger, J.2, Author
Morschhauser, Achim1, Author              
Affiliations:
12.3 Geomagnetism, 2.0 Geophysics, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146030              
2External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: During the IAGA workshop 2018 at Conrad observatory, 30 nonmagnetic theodolites of the Zeiss THEO series were tested for their mechanical and optical properties. Next to an inspection of the instruments, the horizontal circle error (collimation error) and the vertical circle error were determined with the help of a surveyor’s level. While half of the instruments were fine, the others were in need of adjustment or repair. Typical problems requiring repair are sluggish vertical axes and mechanical problems of the coaxial fine-tuning. Typical adjustment problems are the position of the image in the microscope and collimation and vertical circle errors.

Details

show
hide
Language(s): eng - English
 Dates: 2019
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISBN: 978-3-903171-05-3
GFZPOF: p3 PT1 Global Processes
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: 18th Workshop an Geomagnetic Observatory Instruments, Data Acquisition and Processing of the International Association of Geomagnetism and Aeronomy (IAGA)
Source Genre: Book
 Creator(s):
Leonhardt, R., Editor
Leichter, B., Editor
Affiliations:
-
Publ. Info: Wien : Zentralanstalt für Meteorologie und Geodynamik
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: 19 Identifier: ISBN: 978-3-903171-05-3

Source 2

show
hide
Title: Conrad Observatory Journal - COBS Journal: Special issue; 5, 2018
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: - Identifier: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/190220