English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Digital image correlation data from analogue modelling experiments addressing orthogonal and rotational extension at the Tectonic Modelling Lab of the University of Bern (CH)

Zwaan, F., Schreurs, G., Schmid, T., Warsitzka, M., Rosenau, M. (2020): Digital image correlation data from analogue modelling experiments addressing orthogonal and rotational extension at the Tectonic Modelling Lab of the University of Bern (CH). -..
https://doi.org/10.5880/FIDGEO.2020.001

Item is

Files

show Files

Locators

show
hide
Locator:
https://doi.org/10.1016/j.jsg.2019.103946 (Supplementary material)
Description:
Supplement to Zwaan, F./Schreurs, G./Rosenau, M. (2019)

Creators

show
hide
 Creators:
Zwaan, Frank1, Author
Schreurs, Guido1, Author
Schmid, Timothy1, Author
Warsitzka, Michael2, Author              
Rosenau, M.2, Author              
Affiliations:
1External Organizations, ou_persistent22              
24.1 Lithosphere Dynamics, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146034              

Content

show
hide
Free keywords: analogue models of geologic processes, EPOS, Multi-scale laboratories, analogue modelling results, Digital Image Correlation (DIC) / Particle Image Velocimetry (PIV) > StrainMaster (La Vision GmbH), Extension box, SLR camera, Sand > Corundum Sand, Sand > Quartz Sand, Silicon/Silly putty/PDMS, Surface image, X-ray computed tomographic scanner (CT-scan), depression, rift valley, tectonic process > continental_breakup > rifting, tectonic setting > extended terrane setting > continental rift setting
 Abstract: This data set includes the results of digital image correlation of ten brittle-viscous experiments on crustal extension and four benchmark experiments performed at the Tectonic Modelling Lab of the University of Bern (UB). The experiments demonstrate the differences in rift development in orthogonal versus rotation extension. Detailed descriptions of the experiments and monitoring techniques can be found in Zwaan et al. (2019) to which this data set is supplementary. Additional background information concerning the general modelling approach are available in Zwaan et al. (2016). The data presented here consist of movies displaying digital image correlation (DIC) derived surface and internal displacement fields as well as profiles of the lateral cumulative surface displacements. Digital photographs of the experimental surface and digital image cross section of the computed CT-scans were analyzed with DIC (Adam et al., 2005, 2013) techniques to quantify displacements in the image plane at high precision (<0.1 mm). DIC was undertaken with the software DaVis 8.0 (LaVision) applying 2D-DIC (FFT-legacy) multipass processing with a final interrogation window size of 32x32 (CT: 12x12) pixels and 50% (CT: 25%) overlap.

Details

show
hide
Language(s): eng - English
 Dates: 2020
 Publication Status: Finally published
 Pages: -
 Publishing info: Potsdam : GFZ Data Services
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: ...
Source Genre: Series
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: - Identifier: -