  Determination of the 10Be half-life by multicollector ICP-MS and liquid scintillation counting

Chmeleff, J., von Blanckenburg, F., Kossert, K., Jakob, D. (2010): Determination of the 10Be half-life by multicollector ICP-MS and liquid scintillation counting. - Nuclear Instruments and Methods in Physics Research / B, 263, 2, 192-199.
https://doi.org/10.1016/j.nimb.2009.09.012

Item is

Basic

show hide
Item Permalink: https://gfzpublic.gfz-potsdam.de/pubman/item/item_239521 Version Permalink: -
Genre: Journal Article

Files

show Files
hide Files
:
13883.pdf (Any fulltext), 507KB
File Permalink:
-
Name:
13883.pdf
Description:
-
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
eDoc_access: PUBLIC
License:
-

Locators

show

Creators

show
hide
 Creators:
Chmeleff, J.1, Author
von Blanckenburg, Friedhelm2, Author              
Kossert, K.1, Author
Jakob, D.1, Author
Affiliations:
1External Organizations, ou_persistent22              
23.4 Earth Surface Geochemistry, 3.0 Geodynamics and Geomaterials, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146037              

Content

show
hide
Free keywords: 10Be half-life; Liquid scintillation counting; Multicollector ICP-MS
 DDC: 550 - Earth sciences
 Abstract: A new method was designed and used for determining the half-life of the isotope 10Be. The method is based on (1) accurate 10Be/9Be measurements of 9Be-spiked solutions of a 10Be-rich master solution using multicollector ICP mass spectrometry (MC-ICP-MS) and (2) liquid scintillation counting (LSC) using the CIEMAT/NIST method for determining the activity concentrations of the solutions whose 10Be concentrations were determined by mass spectrometry. Important requirements for the success of this approach (a) was the previous coating of glass ampoules filled for counting experiments with 9Be, thereby reducing the risk of the adsorptive loss of 10Be; (b) the removal of Boron from solutions to be measured by MC-ICP-MS by cation chromatography without the introduction of mass fractionation and (c) the accurate determination of the mass bias of 10Be/9Be measurements by ICP-MS which are always affected by the space-charge effect. The mass bias factor was determined to be 1.1862 ± 0.071 for 10Be/9Be from careful fitting and error propagation of ratios of measured Li, B, Si, Cr, Fe, Cu, Sr, Nd, Hf, Tl and U standard solutions of known composition under the same measurement conditions. Employing this factor, an absolute 10Be/9Be ratio of 1.464 ± 0.014 was determined for a first dilution of the 10Be-rich master solution. This solution is now available as an absolute Be ratio standard in AMS measurements. Finally, a half-life of (1.386 ± 0.016) My (standard uncertainty) was calculated. This value is much more precise than previous estimates and was derived from a fully independent set of experiments. In a parallel, fully independent study using the same master solution, Korschinek et al. [35] have determined a half-life of (1.388 ± 0.018) My. The combined half-life and uncertainty amounts to (1.387 ± 0.012) My. We suggest the use of this value in nuclear studies and in studies that make use of cosmogenic 10Be in environmental and geologic samples.

Details

show
hide
Language(s):
 Dates: 2010
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 13883
GFZPOF: PT2 Earth System Dynamics: Coupled Processes and Regional Impact
DOI: 10.1016/j.nimb.2009.09.012
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Nuclear Instruments and Methods in Physics Research / B
Source Genre: Journal, SCI, Scopus
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 263 (2) Sequence Number: - Start / End Page: 192 - 199 Identifier: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/journals367