  Improved detection limits for transient signal analysis of fluid inclusions by inductively coupled plasma atomic emission spectrometry using correlated background correction

Coles, B. J., Gleeson, S. A., Wilkinson, J. J., Ramsey, M. H. (1995): Improved detection limits for transient signal analysis of fluid inclusions by inductively coupled plasma atomic emission spectrometry using correlated background correction. - Analyst, 120, 5, 1421-1425.
https://doi.org/10.1039/an9952001421

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Coles, Barry J.1, Autor
Gleeson, S. A.2, Autor              
Wilkinson, Jamie J.1, Autor
Ramsey, Michael H.1, Autor
Affiliations:
1External Organizations, ou_persistent22              
20 Pre-GFZ, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146023              

Inhalt

einblenden:
ausblenden:
Schlagwörter: INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; TRANSIENT SIGNAL; FLUID INCLUSION; BACKGROUND CORRECTION
 Zusammenfassung: The detection limits for IGP-AES bulk analysis of fluid inclusions;by thermal decrepitation are limited by fluctuations in background emissions from the plasma, The transient nature of the analyte signal prevents sequential off-peak estimation of background levels, The established technique of time-interpolation of background signals measured between the analyses of samples gives somewhat unrealistic estimates because the background is not measured during the decrepitation event, A new procedure, correlated background correction (CBC), uses the high degree of correlation between the relative fluctuations in the spectral background at different wavelengths to effectively predict the background emission under transient analyte peaks, An estimate of the spectral background is made at a wavelength with no analyte signal or spectral interference, in this case 371.030 nm which is otherwise used to measure yttrium, The relative fluctuation in this intensity is used to predict the background emission intensity at all analyte wavelengths during the decrepitation event, The detection limits achieved using CBC are improved typically by a factor of five over those estimated without any correction of background fluctuation, thus increasing the range of sample material amenable to analysis.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 1995
 Publikationsstatus: Final veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Analyst
Genre der Quelle: Zeitschrift, SCI, Scopus
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 120 (5) Artikelnummer: - Start- / Endseite: 1421 - 1425 Identifikator: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/170419