  Überwachung der Bohrungsintegrität – Voraussetzung für die sichere und effiziente Nutzung geothermischer Energie

Reinsch, T., Henninges, J. (2014): Überwachung der Bohrungsintegrität – Voraussetzung für die sichere und effiziente Nutzung geothermischer Energie. - System Erde, 4, 1, 36-41.
https://doi.org/10.2312/GFZ.syserde.04.01.5

Item is

Files

show Files
hide Files
:
GFZ_syserde.04.01.05.pdf (Publisher version), 354KB
Name:
GFZ_syserde.04.01.05.pdf
Description:
-
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show
hide
Description:
Gesamtes Heft

Creators

show
hide
 Creators:
Reinsch, Thomas1, 2, Author              
Henninges, J.1, 3, Author              
Affiliations:
1Vol. 4, Issue 1 (2014), GFZ Journal 2014, System Erde : GFZ Journal, Deutsches GeoForschungsZentrum, , , ou_413889              
2ICGR International Center for Geothermal Research, Geoengineering Centres, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146052              
34.1 Reservoir Technologies, 4.0 Chemistry and Material Cycles, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146039              

Content

show
hide
Free keywords: -
 Abstract: Geothermal energy can play a major role within the future energy supply. For a safe and sustainable provision of geothermal energy, the structural wellbore integrity is an important issue. In order to monitor processes affecting the wellbore integrity, a fibre optic cable has been permanently installed behind the anchor casing of a geothermal well in Iceland. Distributed temperature sensing data has been recorded during the cementation of that casing as well as during the onset of a flow test. Together with numerical studies, temperature data from the cementation could be used to investigate the cement quality behind casing and evaluate the success of the cementation process. Data from the flow testing period could be used to identify a fracture evolution within the cemented annulus during the production of high temperature geothermal fluid. A process influencing the isolation of the cemented annulus, therefore, could be monitored on-line. The application of the distributed temperature sensing technique together with numerical studies proved to be successful in identifying processes affecting the wellbore integrity of a geothermal well.

Details

show
hide
Language(s): deu - German
 Dates: 2014
 Publication Status: Finally published
 Pages: 6
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.2312/GFZ.syserde.04.01.5
GFZPOF: p3 PT7 Ene
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: System Erde
Source Genre: Journal, other, oa
 Creator(s):
Affiliations:
Publ. Info: -
Pages: 86 Volume / Issue: 4 (1) Sequence Number: 5 Start / End Page: 36 - 41 Identifier: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/journals2_413