English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Testing the tunable diode laser system in extreme environments: Measuring high and low CO2 concentrations in both active volcanic and geothermal settings

Mazot, A., Rae, A., Jentsch, A., Britten, K. (2019): Testing the tunable diode laser system in extreme environments: Measuring high and low CO2 concentrations in both active volcanic and geothermal settings. - Journal of Volcanology and Geothermal Research, 376, 1-14.
https://doi.org/10.1016/j.jvolgeores.2019.03.011

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Mazot, Agnes1, Author
Rae, Andrew1, Author
Jentsch, Anna2, Author              
Britten, Karen1, Author
Affiliations:
1External Organizations, ou_persistent22              
24.8 Geoenergy, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146039              

Content

show
hide
Free keywords: -
 Abstract: Measuring CO2 emissions in geothermal and volcanic areas is sometimes difficult because of large areas to cover and sites often inaccessible. Measuring high levels of CO2 concentration can provide information on hidden structure in geothermal areas and recording changes in CO2 concentration on volcanic areas can help monitor the level of volcanic activity. The purpose of this study was to use the Tunable Laser Diode (TDL) absorption spectroscopy method to test levels of CO2 concentrations at two extreme environments: White Island volcano, the most active volcano of New Zealand, with large and concentrated gas fluxes, and Ngapouri geothermal area, a small geothermal area in the Taupo Volcanic Zone, New Zealand, with relatively low and diffuse gas emissions. In 2017, for the first time using TDL at White Island, CO2 concentration measurements performed across the active fumarole fields had the highest CO2 concentrations of 657 ppm. TDL survey measurements were also conducted across fault strands near the Ngapouri geothermal area, and the results complemented CO2 flux results obtained with the accumulation chamber method. Higher CO2 concentrations were measured close to the mapped Ngapouri splays with a maximum of 484 ppm. The maximum CO2 flux measured in the same area was 100 g m−2 day−1 however the highest CO2 fluxes measured along the transects and by the mapped faults were less clear, but the CO2 concentrations increased closer to the fault splays. Advantages and disadvantages of using a TDL system have been described and compared to the accumulation chamber method. The results from the TDL system demonstrated that CO2 concentrations can be used as a tool, with other geophysical tools, for both detecting and highlighting geological structures where no obvious thermal activity is present and for monitoring purposes on active volcanoes.

Details

show
hide
Language(s): eng - English
 Dates: 2019
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: GFZPOF: p3 PT7 Ene
GFZPOF: p3 PT5 Georesources
DOI: 10.1016/j.jvolgeores.2019.03.011
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Volcanology and Geothermal Research
Source Genre: Journal, SCI, Scopus
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 376 Sequence Number: - Start / End Page: 1 - 14 Identifier: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/journals321