Deutsch
 
Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Zero-Offset VSP Monitoring of CO2 Storage: Impedance Inversion and Wedge Modelling at the Ketzin Pilot Site

Götz, J., Lueth, S., Krawczyk, C. M., Cosma, C. (2014): Zero-Offset VSP Monitoring of CO2 Storage: Impedance Inversion and Wedge Modelling at the Ketzin Pilot Site. - International Journal of Geophysics, 2014, 1-15.
https://doi.org/10.1155/2014/294717

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
838928.pdf (Verlagsversion), 9MB
Name:
838928.pdf
Beschreibung:
-
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Götz, J.1, Autor              
Lueth, S.1, Autor              
Krawczyk, Charlotte M.2, Autor
Cosma, Calin2, Autor
Affiliations:
1CGS Centre for Geological Storage, Geoengineering Centres, GFZ Publication Database, Deutsches GeoForschungsZentrum, ou_146050              
2External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: CO2 storage; Ketzin
 Zusammenfassung: At the CO2 storage pilot site near the town of Ketzin (35 km west of Berlin, Germany) the sandstone reservoir at 630 m–650 m depth is thin and heterogeneous. The time-lapse analysis of zero-offset VSP measurements shows that CO2-induced amplitude changes can be observed on near-well corridor stacks. Further, we investigate whether CO2-induced amplitude changes in the monitoring data can be used to derive geometrical and petrophysical parameters governing the migration of CO2 within a brine saturated sandstone aquifer. 2D seismic-elastic modelling is done to test the processing workflow and to perform a wedge modelling study for estimation of the vertical expansion of the CO2 plume. When using the NRMS error as a measure for the similarity between the modelled and recorded repeat traces, the best match is achieved for a plume thickness of 6-7 m within the reservoir sandstone of 8 m thickness. With band limited impedance inversion a velocity reduction at the top of the reservoir of 30%, influenced by casing reverberations as well as CO2 injection, is found. The relation of seismic amplitude to CO2 saturated layer thickness and CO2-induced changes in P-wave velocities are important parameters for the quantification of the injected CO2 volume.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2014
 Publikationsstatus: Final veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: International Journal of Geophysics
Genre der Quelle: Zeitschrift, Scopus
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 2014 Artikelnummer: 294717 Start- / Endseite: 1 - 15 Identifikator: CoNE: https://gfzpublic.gfz-potsdam.de/cone/journals/resource/1501283