English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Software

IndCoils_FGE - A software package for merging Fluxgate and Induction Coil data

Authors
/persons/resource/brunke

Brunke,  Heinz-Peter
2.3 Earth's Magnetic Field, 2.0 Geophysics, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum;

Widmer-Schidrig,  Rudolf
External Organizations;

/persons/resource/monika

Korte,  M.
2.3 Earth's Magnetic Field, 2.0 Geophysics, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum;

External Ressource

http://doi.org/10.5194/gi-6-1-2017
(Supplementary material)

Fulltext (public)
There are no public fulltexts stored in GFZpublic
Supplementary Material (public)
There is no public supplementary material available
Citation

Brunke, H.-P., Widmer-Schidrig, R., Korte, M.(2017): IndCoils_FGE - A software package for merging Fluxgate and Induction Coil data, Potsdam : GFZ Data Services.
https://doi.org/10.5880/GFZ.2.3.2017.002


Cite as: https://gfzpublic.gfz-potsdam.de/pubman/item/item_2793892
Abstract
For frequencies above 30 mHz the instrument intrinsic noise level of typical fluxgate magnetometers used at geomagnetic observatories usually masks ambient magnetic field variations on magnetically quiet days. Natural field variations referred to as pulsations (Pc-1, Pc-2, Pi-1) fall in this band. Usually their intensity is so small that they rarely surpass the instrumental noise of fluxgate magnetometers. INTERMAGNET has set a minimum quality standard for definitive 1 s data (Turbitt, 2014) which can actually hardly be met by fluxgate magnetometers in use by magnetic observatories. Brunke et al. (2017) propose a method to improve 1Hz observatory data by merging data from the proven and tested fluxgate magnetometers currently in use with induction coil magnetometers into a single data stream. This data publication includes the according MATLAB software package implementing the merging of both data sets. The content of the software package and the functionality of each module is described in the content.txt file that is also included in the zip folder. The resulting data are in line with the INTERMAGNET format for 1 s magnetic data, but surpasses the INTERMAGNET 1 s standard by far. The long term stability of the fluxgate data is not affected. The changes to the fluxgate data remain within the range of the instrument intrinsic noise. In addition to the Matlab software, we provide test datasets of one day length kindly provided by the magnetic observatories Niemegk, Conrad and Eskdalemuir.