English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Comparative study on heat extraction from Soultz-sous-Forêts geothermal field using supercritical carbon dioxide and water as the working fluid

Authors

Singh,  Mrityunjay
External Organizations;

Mahmoodpour,  Saeed
External Organizations;

Ershadnia,  Reza
External Organizations;

Soltanian,  Mohamad Reza
External Organizations;

/persons/resource/sass

Sass,  Ingo
4.8 Geoenergy, 4.0 Geosystems, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum;

External Ressource
No external resources are shared
Fulltext (public)
There are no public fulltexts stored in GFZpublic
Supplementary Material (public)
There is no public supplementary material available
Citation

Singh, M., Mahmoodpour, S., Ershadnia, R., Soltanian, M. R., Sass, I. (2023): Comparative study on heat extraction from Soultz-sous-Forêts geothermal field using supercritical carbon dioxide and water as the working fluid. - Energy, 266, 126388.
https://doi.org/10.1016/j.energy.2022.126388


Cite as: https://gfzpublic.gfz-potsdam.de/pubman/item/item_5015338
Abstract
Energy extraction from the deep subsurface requires engineering using a working fluid circulation in well doublet. This study developed a field-scale hydro-thermal model to examine the heat extraction potential from Soultz-sous-Forêts with CO2 and water as the working fluid. A better understanding of the heat extraction mechanism is established by considering the reservoir response and the wellbore heat exchange. Sensitivity analyses are performed for different injection temperatures and flow rates for 50 years. Results show that the wellbore effect is multiple times higher than the reservoir response to the production temperature. Furthermore, lowering the injection temperature eventuates to a smaller temperature reduction at the subsurface, enhancing the overall heat extraction potential with a minor impact on thermal breakthrough. The cold region developed around the injection wellbore may affect the production fluid temperature due to its proximity to the production wellbore near the top of the reservoir. To reach higher heat extraction efficiency, it is essential to use sufficient wellbore spacing. CO2 can be used as working fluid for over 50 years as it does not show significant thermal breakthrough and temperature plume evolution in the reservoir under studied conditions. CO2 shows lower temperature reduction for all injection rates and temperatures for 50 years of operation.