English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Joint evaluation of A10-020, AQG-B07 and iGrav-027 gravimeters at the Borowa Gora Observatory

Dykowski, P., Sękowski, M., Kryński, J., Arnal, M. (2023): Joint evaluation of A10-020, AQG-B07 and iGrav-027 gravimeters at the Borowa Gora Observatory, XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG) (Berlin 2023).
https://doi.org/10.57757/IUGG23-3584

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Dykowski, Przemyslaw1, Author
Sękowski, Marcin1, Author
Kryński, Jan1, Author
Arnal, Maxime1, Author
Affiliations:
1IUGG 2023, General Assemblies, 1 General, International Union of Geodesy and Geophysics (IUGG), External Organizations, ou_5011304              

Content

show
hide
Free keywords: -
 Abstract: Currently, the Borowa Gora Geodetic-Geophysical Observatory maintains 3 modern gravity sensors: A10-020 (since 2008), iGrav-027 (since 2016) and AQG-B07 (since Oct. 2021).Although the instruments considered measure the same phenomena, each of them is based on a different principle of measurement. The presentation aims to evaluate the pros and cons of each gravimeter with respect to the other two by assessing certain characteristics of the instruments (long-, short-term stability, repeatability, noise level). Using AQG and iGrav gravimeters jointly allow to verify their performance in a period of instrumental service/updates, i.e. running continuous gravity measurements while the other gravimeter was maintained.During the period from Oct 2021 until mid-2023 all instruments have been performing regular gravity surveys within their recording capabilities, i.e. the A10-020 on regular monthly basis, the AQG-B07 on regular monthly, sub monthly basis as well as periodic longer tracking series and the iGrav-027 in continuous mode.As the AQG-B07 is the newest type of instrument its performance seems the most interesting. During the presented period AQG showed consistency in tracking gravity variation against the iGrav-027 gravimeter on a few tens of nm/s2 in long term (within a year), and below 10 nm/s2 in short term comparison (couple of weeks of joint gravity measurements). Systematic gravity difference between AQG-B07, A10-020 and reference function realized by the iGrav-027 gravimeter will be discussed. AQG-B07 systematic effects as well as Total Uncertainty is under constant evaluation by iXblue - the gravimeter manufacturer.

Details

show
hide
Language(s): eng - English
 Dates: 2023-07-112023-07-11
 Publication Status: Finally published
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.57757/IUGG23-3584
 Degree: -

Event

show
hide
Title: XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG)
Place of Event: Berlin
Start-/End Date: 2023-07-11 - 2023-07-20

Legal Case

show

Project information

show

Source 1

show
hide
Title: XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG)
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: Potsdam : GFZ German Research Centre for Geosciences
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: - Identifier: -