Joint evaluation of A10-020, AQG-B07 and iGrav-027 gravimeters at the Borowa Gora Observatory

Authors

Dykowski,  Przemyslaw
IUGG 2023, General Assemblies, 1 General, International Union of Geodesy and Geophysics (IUGG), External Organizations;

Sękowski,  Marcin
IUGG 2023, General Assemblies, 1 General, International Union of Geodesy and Geophysics (IUGG), External Organizations;

Kryński,  Jan
IUGG 2023, General Assemblies, 1 General, International Union of Geodesy and Geophysics (IUGG), External Organizations;

Arnal,  Maxime
IUGG 2023, General Assemblies, 1 General, International Union of Geodesy and Geophysics (IUGG), External Organizations;

External Ressource
No external resources are shared
Fulltext (public)
There are no public fulltexts stored in GFZpublic
Supplementary Material (public)
There is no public supplementary material available
Citation

Dykowski, P., Sękowski, M., Kryński, J., Arnal, M. (2023): Joint evaluation of A10-020, AQG-B07 and iGrav-027 gravimeters at the Borowa Gora Observatory, XXVIII General Assembly of the International Union of Geodesy and Geophysics (IUGG) (Berlin 2023).
https://doi.org/10.57757/IUGG23-3584


Cite as: https://gfzpublic.gfz-potsdam.de/pubman/item/item_5020357
Abstract
Currently, the Borowa Gora Geodetic-Geophysical Observatory maintains 3 modern gravity sensors: A10-020 (since 2008), iGrav-027 (since 2016) and AQG-B07 (since Oct. 2021).Although the instruments considered measure the same phenomena, each of them is based on a different principle of measurement. The presentation aims to evaluate the pros and cons of each gravimeter with respect to the other two by assessing certain characteristics of the instruments (long-, short-term stability, repeatability, noise level). Using AQG and iGrav gravimeters jointly allow to verify their performance in a period of instrumental service/updates, i.e. running continuous gravity measurements while the other gravimeter was maintained.During the period from Oct 2021 until mid-2023 all instruments have been performing regular gravity surveys within their recording capabilities, i.e. the A10-020 on regular monthly basis, the AQG-B07 on regular monthly, sub monthly basis as well as periodic longer tracking series and the iGrav-027 in continuous mode.As the AQG-B07 is the newest type of instrument its performance seems the most interesting. During the presented period AQG showed consistency in tracking gravity variation against the iGrav-027 gravimeter on a few tens of nm/s2 in long term (within a year), and below 10 nm/s2 in short term comparison (couple of weeks of joint gravity measurements). Systematic gravity difference between AQG-B07, A10-020 and reference function realized by the iGrav-027 gravimeter will be discussed. AQG-B07 systematic effects as well as Total Uncertainty is under constant evaluation by iXblue - the gravimeter manufacturer.