Deutsch
 
Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Triple Isotope Fractionation Exponents of Elements Measured by MC-ICP-MS — An Example of Mg

Urheber*innen

Tatzel,  Michael
External Organizations;

Vogl,  Jochen
External Organizations;

Rosner,  Martin
External Organizations;

/persons/resource/henehan

Henehan,  Michael
3.3 Earth Surface Geochemistry, 3.0 Geochemistry, Departments, GFZ Publication Database, Deutsches GeoForschungsZentrum;

Tütken,  Thomas
External Organizations;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in GFZpublic verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Tatzel, M., Vogl, J., Rosner, M., Henehan, M., Tütken, T. (2019): Triple Isotope Fractionation Exponents of Elements Measured by MC-ICP-MS — An Example of Mg. - Analytical Chemistry, 91, 22, 14314-14322.
https://doi.org/10.1021/acs.analchem.9b02699


Zitierlink: https://gfzpublic.gfz-potsdam.de/pubman/item/item_5000158
Zusammenfassung
In most chemical reactions, stable isotopes are fractionated in a mass-dependent manner, yielding correlated isotope ratios in elements with three or more stable isotopes. The proportionality between isotope ratios is set by the triple isotope fractionation exponent θ that can be determined precisely for, e.g., sulfur and oxygen by IRMS, but not for metal(loid) elements due to the lower precision of MC-ICP-MS analysis and smaller isotopic variations. Here, using Mg as a test case, we compute a complete metrologically robust uncertainty budget for apparent θ values and, with reference to this, present a new measurement approach that reduces uncertainty on θ values by 30%. This approach, namely, direct educt-product bracketing (sample–sample bracketing), allows apparent θ values of metal(loid) isotopes to be determined precisely enough to distinguish slopes in three-isotope space. For the example of Mg, we assess appropriate quality control standards for interference-to-signal ratios and report apparent θ values of carbonate–seawater pairs. We determined apparent θ values for marine biogenic carbonates, where the foraminifera Globorotalia menardii yields 0.514 ± 0.005 (2 SD), the coral Porites, 0.515 ± 0.006 (2 SD), and two specimens of the giant clam Tridacna gigas, 0.508 ± 0.007 (2 SD) and 0.509 ± 0.006 (2 SD), documenting differences in the uptake pathway of Mg among marine calcifiers. The capability to measure apparent θ values more precisely adds a new dimension to metal(loid) δ values, with the potential to allow us to resolve different modes of fractionation in industrial and natural processes.